The data types of the S7-300 are divided into the following three types: basic data types, composite data types, and parameter types. The clock Date_And_Time belongs to the composite data type.
Date_And_Time is a complex data type containing 8 bytes. Byte0-Byte7 corresponds to the data of year, month, day, hour, minute, second, millisecond, and day of the week, occupying 8 bytes. The Sunday code is 1, and the Monday to Saturday code is 2 to 7, respectively, such as:
DT#2004_07_15_12:30:15.200 is 12:30: 15.2 seconds on July 15, 2004.
The clock can be set and read using SFC0 and SFC1.

Date and time (DATE-AND-TIME)

The system clock for the S7-300plc uses the "DATE-AND-TIME" data type.
Used to store data for year, month, day, hour, minute, second, millisecond, and day of the week. Occupies 8 bytes, the data type is saved in BCD format. Such as: DT#2004_07_15_12:30:15.200 is 12:30: 15.2 seconds on July 15, 2004.
The following example represents Thursday, August 5, 2004, 8:12:5.250 seconds. It also gives the contents of the time and date data contained in each byte.
Byte content example
0å¹´B#16#04
January B#16#08
2nd B#16#05
3 hours B#16#08
4 minutes B#16#05
5 seconds B#16#05
Hundred and ten digits of 6 milliseconds B#16#25
7 (high 4 digits) milliseconds digit value B#16#0
S5T# format

The timer uses different types of time. The timer uses the S5T# format: S5T#aD_bH_cM_dS_eMS, where a, b, c, d, and e are the values ​​of day, hour, minute, second, and millisecond, respectively. Underlined.
The S5TIME time base and the corresponding time range are as follows:
The time values ​​are defined in the following two formats:
1) W#16#wxyz
Ow=time base (ie time interval or precision)
The time value of oxyz=BCD format can only be used for STL programming.
2) S5T#aH_bbM_ccS_dddMS
Oa=hour, bb=minute, cc=second, dd=millisecond
o In this case, the time base is automatically selected, and the value is taken from the time base to the next lower value.
o The maximum value you can enter is 9,990 seconds, or 2H_46M_30S.
IEC time - TIMEIEC time (international standard), the minimum time base is 1ms, the maximum unit of measurement is day (D), signed, and the format is T#0D_1H_1M_0S_0MS.

Centrifugal fans

EQM series motors are designed with advanced electronic control technology, make the motor efficiency greatly increased,the external structure design of EQM series motors will maintain the similar external structure design as YZF series motors,motor accessories such as fan blades, rings or grids.brackets for EQM motors are the same as YZF series`. therefore EQM series motors can completely replace the YZF series motors without any other changes.Comparing with YZF series motors, EQM motors display an obvious advantage in energy saving. saving up to 70%.It can greatly reduce the electricity cost for motor operation and carbon dioxide emissions Not only that.due to the heating of EQM series motors themselves are very low.it would lead to the entire