Model NO.: YJV/YJV22/YJV32/YJV42
-
Voltage: Low and Medium Voltage Cable
-
Insulation Material: XLPE
-
Material Shape: Round Wire
-
Certification: ISO, CCC, CE
-
Brand: Huatong
-
Experience: 30years
-
Delivery Time: 5~15 Official Days
-
Transport Package: Wooden Drum, Steel Drum, Steel Wooden Drum
-
Origin: China
-
Application: Construction, Overhead, Underground, Industrial, Power Station
-
Current: DC & AC
-
Sheath Material: PVC
-
Wire Core Material: Copper
-
Model: Yjv/Yjv22/Yjv32/Yjv42
-
Factory Area: 100000m2
-
Delivery Length: Accord with The Request
-
Trademark: Huatong
-
Specification: 1.1m*1.1*1.1m
-
HS Code: 8544601200
Product Description3.6/6KV XLPE insulated power cable underground use
  (1)Production capacity:5000km/month
  (2)MOQ:1km
  (3)Delivery:5~15 officail days.
  (4)Standards:IEC,ASTM,DIN,BS; or according to customers' requirements.
1. Specification
1)Conductors:copper
 2)Both armored and non-armored type power cables are available.
 3)Voltage rating: 0.6/1kV 3.6/6kV 6/10kV 8.7/15kV 26/35kV.
 4)PVC or XLPE sheathed.
 5)Number of cable cores: one core (Single core),two cores(Double cores),three cores,
   Four cores (Four Equal-section-area cores or three equal-section area cores and one smaller section area neutral core),
      Five cores (Five equal-area cores or three equal-section
area cores and two smaller section area neutral cores).
  6)Standards: IEC 60502.IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. Or other special characteristics as customers request.
2.Characteristics of Cable
 1)Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
 2)Installing temperature of cable should not be less than 0°C
 3)Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
 4)Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
 5)Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
3.Number of Cores & Nominal Cross-section Area
Number of Cores |
1 |
2 |
3 |
3+1 |
4 |
3+2 |
4+1 |
5 |
Section Area (mm2) |
4 - 500 |
2.5 - 500 |
2.5 - 300 |
4 - 300 |
2.5 - 300 |
2.5 -300 |
4 - 300 |
2.5 - 95 |
4.Installation:
1)The installation temperature should not over 20ºC, If the ambient temperature is lower than 0ºC, the cable should be preheated.
2)The bending radius of cable should not less than 8 times.
3)After installantion, the cable should with stand voltage test for 15min. 3.5kv D.C.
In air:
1) As the single core cable laying in parallel, the distance between the cable's center is 2 times (for cables which cross section area of conductor ≤185mm2) and
90mm (for cables which cross sectional area of conductor≥240mm2)
2)Ambient temperature: 30ºC
3)Max. temperature of conductor: 70ºC
4)Rating factors of current rating for ambient temperature:
Air temperature |
20ºC |
25ºC |
35ºC |
40ºC |
45ºC |
Rating factors |
1.12 |
1.06 |
0.94 |
0.87 |
0.79 |
In ground:
1)When the single core cables are installed separately, the distance between the cable's center is 2 times of the cable diameter.
2)Ambient temperature: 25ºC.
3)Max. temperature of conductor: 70ºC.
4)Soil thermour resistivity: 1.0ºC. m/w.
5)Depth: 0.7m
6)Rating factors under different ambient temp.:
Air temperature |
15ºC |
20ºC |
30ºC |
35ºC |
Rating factors |
1.11 |
1.05 |
0.94 |
0.88 |
5.XLPE Insulated electric cable
Type |
Description |
Application |
Cu Core |
Al Core |
YJV ZR-YJV |
YJLV ZR-YJLV |
Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable |
Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force. |
YJV22 ZR-YJV22 |
YJLV22 ZR-YJLV22 |
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable |
Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force. |
YJV32 ZR-YJV32 |
YJLV32 ZR-YJLV32 |
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable |
Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force. |
YJV42 ZR-YJV42 |
YJLV42 ZR-YJLV42 |
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable |