CU/XLPE/LSZH/SWA/LSZH (2 Cores - 5 Cores) XLPE Insulated, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable Power Cable Application: Power Cable Construction: Conductor: Plain annealed copper, class1 solid or class 2 stranded as per IEC 60228. Insulation: Cross-linked polyethlene (XLPE) compound as per IEC 60502-1. Insulation Colour: 2 Assembly: Cores cabled together with PP filler and covered with non-woven tape. Recommended rated voltages U0 Routine test voltages Maximum conductor temperatures for different types of insulating compound Operating Temperature: -15°C to 90°C Reference Standards Installation Reference Dimension 2 Cores Thickness Thickness Diameter of Thickness 3 Cores Thickness Thickness Diameter Thickness 4 Cores Thickness Thickness Diameter Thickness 5 Cores Thickness Thickness Diameter Thickness CU/XLPE/LSZH/SWA/LSZH (2 Cores - 5 Cores) XLPE Insulated, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable Power Cable Application: Power Cable Construction: Conductor: Plain annealed copper, class1 solid or class 2 stranded as per IEC 60228. Insulation: Cross-linked polyethlene (XLPE) compound as per IEC 60502-1. Insulation Colour: 2 Assembly: Cores cabled together with PP filler and covered with non-woven tape. Recommended rated voltages U0 Routine test voltages Maximum conductor temperatures for different types of insulating compound Operating Temperature: -15°C to 90°C Reference Standards Installation Reference Dimension 2 Cores Thickness Thickness Diameter of Thickness 3 Cores Thickness Thickness Diameter Thickness
A communication cable is a type of cable that is used to transmit data, signals, or information between two or more devices or locations. It is typically made up of multiple wires or fibers that are enclosed in a protective sheath. Data Communication Cable,Shielded Communication Wire,Communication and Data Cable,485 Communication Cable Ruitian Cable CO.,LTD. , https://www.rtlinecable.com
These power cable for fixed installations such as distribution networks or industrial installations.
Such as Plant engineering; Industrial machinery; Heating and air-conditioning systems; Power stations; Stage applications etc.
Armoured cable suitable for direct burial.
Â
                  Flexible class 5 or tinned conductor could be offer upon request.
Number of Cores
Color Code to IEC 60502-1
Color Code to BS 5467
Red & BlackÂ
Brown & Blue
3
Red, Yellow and BlueÂ
Brown, Black and Grey
4
Red, Yellow, Blue and Black
Blue, Brown, Black and Grey
5
Red, Yellow, Blue, Black and
Green / YellowGreen / Yellow, Blue, Brown,
Black and Grey
Bedding: Low smoke zero halogen (LSZH) compound ST8 (90°C) of IEC 60502-1.
Bedding Colour: Black or other color as per customer request.
Armour: Galvanized steel wire armoured (SWA).
Outer Sheath: Low smoke zero halogen (LSZH) compound ST8 (90°C) of IEC 60502-1.
Outer Sheath Colour: Black or other color as per customer request.
Â
Highest system voltage
      (U m ) (kV)                                          Rated voltage (U 0 ) (kV)
Categories A and BÂ
Category C
1.2
0.6
0.6
Rated voltage U 0 (kV)Â
0.6
Test voltage (kV)Â
3.5
    Maximum conductor temperature (°C)
Normal operationÂ
Short-circuit (5 s maximum duration)
90
250
Test Voltage: 3.5 kV for 5 minutes
Design Specification: BS6724
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN50267-2-1, BS EN50267-2-2
Min.Bending Radius (mm): 8 x cable overall diameter
Max.Pulling Tension (N/mm 2 ): 70
Low Voltage Power Cable (0.6/1 kV)
XLPE insulated, copper conductor, Steel Wire Armour, LSZH cable
Nominal Conductor Area(mm2)
No.and
Diameter of
Wires
(no./mm)
ofÂ
Insulation
(mm)Diameter
Under Armour
(mm)
of Bending
(mm)
Armour Wire
(mm)
of Sheath
(mm)Overall
Diameter
(mm)Approximate
Weight
(kg/km)
2X1.5
7/0.53
0.7
8
1
0.8
1.8
13.2
325
2X2.5
7/0.67
0.7
8.8
1
0.8
1.8
14
372
2X4
7/0.85
0.7
9.9
1
0.8
1.8
15.1
438
2X6
7/1.04
0.7
11
1
1.25
1.8
17.1
645
2X10
7/1.35
0.7
12.9
1
1.25
1.8
19
806
2X16
7/1.70
0.7
15
1
1.25
1.8
21.1
1015
2X25
7/2.14
0.9
18.4
1
1.6
1.8
25.2
1517
2X35
7/2.52
0.9
20.7
1
1.6
1.8
27.5
1830
2X50
19/1.78
1
23.8
1
1.6
1.9
30.8
2259
2X70
19/2.14
1.1
28.2
1.2
2
2.1
36.4
3249
2X95
19/2.52
1.1
32
1.2
2
2.2
40.4
4043
2X120
37/2.03
1.2
35.6
1.2
2.5
2.4
45.4
5254
2X150
37/2.25
1.4
39.9
1.4
2.5
2.5
49.9
6211
2X185
37/2.52
1.6
44.5
1.4
2.5
2.7
54.9
7403
2X240
61/2.25
1.7
50.5
1.6
2.5
2.9
61.3
9175
2X300
61/2.52
1.8
55.8
1.6
2.5
3.1
67
10939
2x400
61/2.85
2
62.5
1.6
3.15
3.4
75.6
14295
2x500
61/3.20
2.2
70
1.8
3.15
3.6
83.5
17282
2x630
127/2.52
2.4
78.7
1.8
3.15
3.9
92.8
21253
2x800
127/2.85
2.6
88.5
2
3.15
4.3
103.4
26200
2x1000
127/3.20
2.8
98.4
2
3.15
4.6
113.9
31788
Nominal Conductor Area
(mm2)No.and
Diameter of
Wires
(no./mm)
of
Insulation
(mm)Diameter
Under Armour
(mm)
of
Bending
(mm)
of
Armour Wire
(mm)
of
Sheath
(mm)Overall
Diameter
(mm)Approximate
Weight
(kg/km)
3X1.5
7/0.53
0.7
8.4
1
0.8
1.8
13.6
361
3X2.5
7/0.67
0.7
9.3
1
0.8
1.8
14.5
420
3X4
7/0.85
0.7
10.5
1
1.25
1.8
16.6
629
3X6
7/1.04
0.7
11.7
1
1.25
1.8
17.8
742
3X10
7/1.35
0.7
13.7
1
1.25
1.8
19.8
954
3X16
7/1.70
0.7
16
1
1.6
1.8
22.8
1372
3X25
7/2.14
0.9
19.7
1
1.6
1.8
26.5
1857
3X35
7/2.52
0.9
22.2
1
1.6
1.8
29
2281
3X50
19/1.78
1
25.5
1
2
2
33.5
3118
3X70
19/2.14
1.1
30.2
1.2
2
2.1
38.4
4107
3X95
19/2.52
1.1
34.3
1.2
2
2.3
42.9
5217
3X120
37/2.03
1.2
38.6
1.4
2.5
2.5
48.6
6808
3X150
37/2.25
1.4
42.8
1.4
2.5
2.6
53
8027
3X185
37/2.52
1.6
47.7
1.4
2.5
2.8
58.3
9655
3X240
61/2.25
1.7
54.1
1.6
2.5
3
65.1
12085
3X300
61/2.52
1.8
59.8
1.6
2.5
3.2
71.2
14540
3X400
61/2.85
2
67.5
1.8
3.15
3.5
80.8
19015
3x500
61/3.20
2.2
75.1
1.8
3.15
3.8
89
23090
3x630
127/2.52
2.4
84.9
2
3.15
4.1
99.4
28777
3x800
127/2.85
2.6
95
2
3.15
4.5
110.3
35573
3x1000
3x1000
2.8
105.7
2
3.15
4.9
121.8
43549
Nominal Conductor Area
(mm2)No.and
Diameter of
Wires
(no./mm)
of
Insulation
(mm)Diameter
Under Armour
(mm)
of
Bending
(mm)
of
Armour Wire
(mm)
of
Sheath
(mm)Overall
Diameter
(mm)Approximate
Weight
(kg/km)
4X1.5
7/0.53
0.7
9.2
1
0.8
1.8
14.4
406
4X2.5
7/0.67
0.7
10.2
1
1.25
1.8
16.3
600
4X4
7/0.85
0.7
11.5
1
1.25
1.8
17.6
718
4X6
7/1.04
0.7
12.9
1
1.25
1.8
19
859
4X10
7/1.35
0.7
15.2
1
1.6
1.8
22
1259
4X16
7/1.70
0.7
17.7
1
1.6
1.8
24.5
1628
4X25
7/2.14
0.9
21.8
1
1.6
1.8
28.6
2237
4X35
7/2.52
0.9
24.6
1
1.6
1.9
31.6
2794
4X50
19/1.78
1
28.7
1.2
2
2.1
36.9
3862
4X70
19/2.14
1.1
33.5
1.2
2
2.3
42.1
5086
4X95
19/2.52
1.1
38.5
1.4
2.5
2.5
48.5
7023
4X120
37/2.03
1.2
42.9
1.4
2.5
2.6
53.1
8428
4X150
37/2.25
1.4
47.6
1.4
2.5
2.8
58.2
10016
4X185
37/2.52
1.6
53.5
1.6
2.5
3
64.5
12185
4X240
61/2.25
1.7
60.3
1.6
3.15
3.3
73.2
16156
4X300
61/2.52
1.8
67
1.8
3.15
3.5
80.3
19518
4X400
61/2.85
2
75.2
1.8
3.15
3.8
89.1
24020
4x500
61/3.20
2.2
84.1
2
3.15
4.1
98.6
29408
4x630
127/2.52
2.4
94.7
2
3.15
4.5
110
36693
4x800
127/2.85
2.6
106
2
3.15
4.9
122.1
45523
4x1000
127/3.20
2.8
117.9
2
3.15
5.3
134.8
55907
Nominal Conductor Area
(mm2)No.and
Diameter of
Wires
(no./mm)
of
Insulation
(mm)Diameter
Under Armour
(mm)
of
Bending
(mm)
of
Armour Wire
(mm)
of
Sheath
(mm)Overall
Diameter
(mm)Approximate
Weight
(kg/km)
5x1.5
7/0.53
0.7
10.1
1
1.25
1.8
16.2
573
5X2.5
7/0.67
0.7
11.2
1
1.25
1.8
17.3
671
5X4
7/0.85
0.7
12.7
1
1.25
1.8
18.8
812
5X6
7/1.04
0.7
14.2
1
1.25
1.8
20.3
981
5X10
7/1.35
0.7
16.7
1
1.6
1.8
23.5
1446
5X16
7/1.70
0.7
19.6
1
1.6
1.8
26.4
1892
5X25
7/2.14
0.9
24.2
1
1.6
1.9
31.2
2644
5x35
7/2.52
0.9
27.7
1.2
2
2.1
35.9
3648
5x50
19/1.78
1
31.8
1.2
2
2.2
40.2
4580
5x70
19/2.14
1.1
37.2
1.2
2.5
2.4
47
6507
5X95
19/2.52
1.1
42.8
1.4
2.5
2.6
53
8370
5X120
37/2.03
1.2
47.6
1.4
2.5
2.8
58.2
10113
5X150
37/2.25
1.4
53.3
1.6
2.5
3
64.3
12131
5X185
37/2.52
1.6
59.5
1.6
2.5
3.2
70.9
14693
5X240
61/2.25
1.7
67.5
1.8
3.15
3.5
80.8
19549
5X300
61/2.52
1.8
74.6
1.8
3.15
3.8
88.5
23599
5X400
61/2.85
2
84.1
2
3.15
4.1
98.6
29242
5x500
61/3.20
2.2
93.6
2
3.15
4.4
108.7
35726
5x630
127/2.52
2.4
105.4
2
3.15
4.9
121.5
44748
5x800
127/2.85
2.6
118.1
2
3.15
5.3
135
55631
5x1000
127/3.20
2.8
131.4
2
3.15
5.8
149.3
68518
Supplying you with customized iec60502 0.6 / 1 kv 2 cores -5 cores xlpe insulation lszh sheath steel wire armoured power cable, it is one of the reliable iec60502 0.6 / 1 kv 2 cores -5 cores xlpe insulation Lszh sheath steel wire armoured power cable manufacturers and suppliers, welcome to wholesale our products at good price from our factory.
Hot Tags:Â Armored Power Cable, Xlpe Armoured Cable Specifications, Armoured Cable, Armored Electric Cable, Steel Wire Armoured Xlpe Cable, 0.6/1 Kv Power Cable, 2 Cores To 5 Cores Power Cable, 0.6 /1 Kv Power Cable, Cu Xlpe PVC Cable
Packing & Shipping:
Why Choose Us ?
1. We have a large production base, and advanced production equipmentÂ
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Free issue:packaging list,invoice
5. Powerful technology team
6. Strict quality assurance system and perfect testing means
7. Advanced process equipment
8. Delivery on time
9. Our cable sales to Middle East,Africa,Russia,Southeast Asia, etc.
10.We have a good reputation in the overseas.
FAQ
Q: Are you trading company or manufacturer ?
A: We are factory.
Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 10-20 days if the goods are not in stock,
it is according to quantity.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
Q: What is your terms of payment ?
A: 30% T/T in advance,70% T/T balance before shipment
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Any needs or question, please contact me Mobile:+86-15838290725 , we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperation.
0.6/1kV YJV32 Copper Conductor Steel Armored 3x150+1x70 Power Cable
These power cable for fixed installations such as distribution networks or industrial installations.
Such as Plant engineering; Industrial machinery; Heating and air-conditioning systems; Power stations; Stage applications etc.
Armoured cable suitable for direct burial.
Â
                  Flexible class 5 or tinned conductor could be offer upon request.
Number of Cores
Color Code to IEC 60502-1
Color Code to BS 5467
Red & BlackÂ
Brown & Blue
3
Red, Yellow and BlueÂ
Brown, Black and Grey
4
Red, Yellow, Blue and Black
Blue, Brown, Black and Grey
5
Red, Yellow, Blue, Black and
Green / YellowGreen / Yellow, Blue, Brown,
Black and Grey
Bedding: Low smoke zero halogen (LSZH) compound ST8 (90°C) of IEC 60502-1.
Bedding Colour: Black or other color as per customer request.
Armour: Galvanized steel wire armoured (SWA).
Outer Sheath: Low smoke zero halogen (LSZH) compound ST8 (90°C) of IEC 60502-1.
Outer Sheath Colour: Black or other color as per customer request.
Â
Highest system voltage
      (U m ) (kV)                                          Rated voltage (U 0 ) (kV)
Categories A and BÂ
Category C
1.2
0.6
0.6
Rated voltage U 0 (kV)Â
0.6
Test voltage (kV)Â
3.5
    Maximum conductor temperature (°C)
Normal operationÂ
Short-circuit (5 s maximum duration)
90
250
Test Voltage: 3.5 kV for 5 minutes
Design Specification: BS6724
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN50267-2-1, BS EN50267-2-2
Min.Bending Radius (mm): 8 x cable overall diameter
Max.Pulling Tension (N/mm 2 ): 70
Low Voltage Power Cable (0.6/1 kV)
XLPE insulated, copper conductor, Steel Wire Armour, LSZH cable
Nominal Conductor Area(mm2)
No.and
Diameter of
Wires
(no./mm)
ofÂ
Insulation
(mm)Diameter
Under Armour
(mm)
of Bending
(mm)
Armour Wire
(mm)
of Sheath
(mm)Overall
Diameter
(mm)Approximate
Weight
(kg/km)
2X1.5
7/0.53
0.7
8
1
0.8
1.8
13.2
325
2X2.5
7/0.67
0.7
8.8
1
0.8
1.8
14
372
2X4
7/0.85
0.7
9.9
1
0.8
1.8
15.1
438
2X6
7/1.04
0.7
11
1
1.25
1.8
17.1
645
2X10
7/1.35
0.7
12.9
1
1.25
1.8
19
806
2X16
7/1.70
0.7
15
1
1.25
1.8
21.1
1015
2X25
7/2.14
0.9
18.4
1
1.6
1.8
25.2
1517
2X35
7/2.52
0.9
20.7
1
1.6
1.8
27.5
1830
2X50
19/1.78
1
23.8
1
1.6
1.9
30.8
2259
2X70
19/2.14
1.1
28.2
1.2
2
2.1
36.4
3249
2X95
19/2.52
1.1
32
1.2
2
2.2
40.4
4043
2X120
37/2.03
1.2
35.6
1.2
2.5
2.4
45.4
5254
2X150
37/2.25
1.4
39.9
1.4
2.5
2.5
49.9
6211
2X185
37/2.52
1.6
44.5
1.4
2.5
2.7
54.9
7403
2X240
61/2.25
1.7
50.5
1.6
2.5
2.9
61.3
9175
2X300
61/2.52
1.8
55.8
1.6
2.5
3.1
67
10939
2x400
61/2.85
2
62.5
1.6
3.15
3.4
75.6
14295
2x500
61/3.20
2.2
70
1.8
3.15
3.6
83.5
17282
2x630
127/2.52
2.4
78.7
1.8
3.15
3.9
92.8
21253
2x800
127/2.85
2.6
88.5
2
3.15
4.3
103.4
26200
2x1000
127/3.20
2.8
98.4
2
3.15
4.6
113.9
31788
Nominal Conductor Area
(mm2)No.and
Diameter of
Wires
(no./mm)
of
Insulation
(mm)Diameter
Under Armour
(mm)
of
Bending
(mm)
of
Armour Wire
(mm)
of
Sheath
(mm)Overall
Diameter
(mm)Approximate
Weight
(kg/km)
3X1.5
7/0.53
0.7
8.4
1
0.8
1.8
13.6
361
3X2.5
7/0.67
0.7
9.3
1
0.8
1.8
14.5
420
3X4
7/0.85
0.7
10.5
1
1.25
1.8
16.6
629
3X6
7/1.04
0.7
11.7
1
1.25
1.8
17.8
742
3X10
7/1.35
0.7
13.7
1
1.25
1.8
19.8
954
3X16
7/1.70
0.7
16
1
1.6
1.8
22.8
1372
3X25
7/2.14
0.9
19.7
1
1.6
1.8
26.5
1857
3X35
7/2.52
0.9
22.2
1
1.6
1.8
29
2281
3X50
19/1.78
1
25.5
1
2
2
33.5
3118
3X70
19/2.14
1.1
30.2
1.2
2
2.1
38.4
4107
3X95
19/2.52
1.1
34.3
1.2
2
2.3
42.9
5217
3X120
37/2.03
1.2
38.6
1.4
2.5
2.5
48.6
6808
3X150
37/2.25
1.4
42.8
1.4
2.5
2.6
53
8027
3X185
37/2.52
1.6
47.7
1.4
2.5
2.8
58.3
9655
3X240
61/2.25
1.7
54.1
1.6
2.5
3
65.1
12085
3X300
61/2.52
1.8
59.8
1.6
2.5
3.2
71.2
14540
3X400
61/2.85
2
67.5
1.8
3.15
3.5
80.8
There are various types of communication cables, including:
1. Ethernet Cable: This is the most common type of communication cable used for wired internet connections. It is used to connect devices such as computers, routers, and switches.
2. Coaxial Cable: This cable is commonly used for cable television (CATV) and broadband internet connections. It consists of a central conductor surrounded by insulation, a metallic shield, and an outer protective sheath.
3. Fiber Optic Cable: This type of cable uses thin strands of glass or plastic fibers to transmit data through light signals. It is known for its high bandwidth and is commonly used for long-distance communication and high-speed internet connections.
4. USB Cable: Universal Serial Bus (USB) cables are used to connect devices such as computers, printers, and smartphones. They are designed to transmit both power and data signals.
5. HDMI Cable: High-Definition Multimedia Interface (HDMI) cables are used to transmit high-quality audio and video signals between devices such as televisions, DVD players, and gaming consoles.
Communication cables play a crucial role in various industries and applications, including telecommunications, networking, broadcasting, and home entertainment. They enable the transfer of data, voice, and video signals, facilitating efficient communication between devices and locations.
0.6/1kv Yjv32 Copper Conductor Steel Armored 3X150+1X70 Power Cable
Model NO.: YJV32 Power Cable
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, SGS
Model: Yjv32
Brand: Hongda
Standard: IEC 60502-1
Rated Voltage: 0.6/1 Kv
Use: Underground
Trademark: Hongda
Transport Package: Drum or as Customer Require
Specification: 1.5mm2 to 400mm2
Origin: China
HS Code: 8544492100
Model NO.: YJV32 power cable
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, SGS
Model: Yjv32
Brand: Hongda
Standard: IEC 60502-1
Rated Voltage: 0.6/1 Kv
Use: Underground
Trademark: Hongda
Transport Package: Drum or as Customer Require
Specification: 1.5mm2 to 400mm2
Origin: China
HS Code: 8544492100
0.6/1kV YJV32 Copper Conductor Steel Armored 3x150+1x70 Power Cable