Rolling Code Hcs301 Remote Gate Controller for Europe Market

Model NO.: KL-K103X
Frequency: 433MHz/315MHz, Optional
Decoding Type: Learning Code(1527), Fixed Code(2262)
Output Mode: Switching on/off(Dry Contact)
Working Mode: Momentary / Toggle / Latching
Max Load: 7A (Relay Contact)
Size: 62*43*30mm
Trademark: Kelvin
Transport Package: Carton
Specification: 62*43*30mm
Origin: Shenzhen, China
HS Code: 8526920000

Rolling Code Hcs301 Remote Gate Controller for Europe Market
Operation Method:

1. Match code:
Hold learning button and learning indicator light blinks, then press a buttons of remote control, if indicator lights flashes 3 times, match code successfully. Maximum 20 remote controls can be matched.
Pls note that KL-K103X can learn any data code. It means it can be controlled by whichever button you press on the remote while matching.

2. Delete code:
Hold learning button till the indicator LED lights and then off, delete successfully.

3. Set working mode:
S1 & S2 program the sequence as follows:
Jumper on S1→ Toggle
Jumper on S2→ Latching
No Jumper on S1 &S2→ Momentary

Rolling Code Hcs301 Remote Gate Controller for Europe Market
Rolling Code Hcs301 Remote Gate Controller for Europe Market

Rolling Code Hcs301 Remote Gate Controller for Europe Market




Rolling Code Hcs301 Remote Gate Controller for Europe Market

Tech Data:

DC 12V 1-Channel Remote Control Switch KL-K103X

Input DC 12V (DC9V, 24V is customized)
Channels 1
Working Current 8mA
Working Frequency 433MHz / 315MHz (other frequency is customized)
Receiver Sensitivity -103dBm
Decoding Type Learning Code(EV1527) / Fixed Code(2262)
Output Mode Switching Signal (Dry Contact)
Working Mode Momentary / Toggle / Latching
Max Load of Relay Contact 7A
Dimension 44*37*20mm

 
Working Mode:

1. Momentary: Press remote button A, the corresponding relay on the receiver is on; release button A, the relay is off, the same as others.

2. Toggle: Press remote button A, the corresponding relay on the receiver is on; press button A again, the relay is off, the same as others.

3. Latching: Press remote button A, the relay A is on, B is off; press button B, the replay B is on, A is off.

Wiring Way & Diagram:

B=Normally Closed, G=Common, K=Normally Open
Rolling Code Hcs301 Remote Gate Controller for Europe Market

 

Shipping

1) Express: DHL, FedEx, UPS, TNT, EMS, etc.

2) By air

3) By sea

4) By special line

Depends on buyer's requirement. 

 
Rolling Code Hcs301 Remote Gate Controller for Europe Market

11.1V Lithium-ion Battery Pack

When using lead-acid batteries, frequent maintenance and replacement is necessary. This will increase the cost for the investment in batteries. Although the investment of lithium batteries could be higher at first, you can enjoy the good return in the long term. The lithium batteries gives a longer lifespan as you can discharge them for more cycles and use with less maintenance before replacement.


The Advantages of Lithium-ion Battery Pack

1.Higher energy density

The higher energy density of lithium-ion battery pack means we are going to get more power out of the same physical size cell than we could get from a lead-acid battery. So when using lithium-ion battery for electronic gear, it means more runtime but less weight.

2.Less weight

Less weight could be a big advantage for most electronic applications that need to be in a compact size and lightweight for use, including mobile applications, robots, drones, floor scrubbers, RVs. A lot of power is used for those devices, so less weight would be certainly an advantage for mobile applications.

3.Thousands VS hundreds of cycles

More cycles are an advantage by a lithium product we`re gonna get. You know the lithium batteries could provide thousands of cycles versus lead-acid batteries which only offer hundreds of cycles. It is a big difference in the cycling ability of lithium over lead-acid batteries.

4.Charge and discharge rate

We are able to discharge a lithium product much quicker than that of a lead-acid product and get the same capacity. If the lithium-ion battery pack is discharged to 80%, you can still get a good lifespan. But doing that with a lead-acid battery will damage its lifespan. Generally, a lead-acid battery can only use fifty percent of the discharge. The recharge time is quicker on a lithium product as well especially if we have a charger that`s large enough to put the capacity back. The lithium-ion battery packs have a low self-discharge rate of only 1-2% per month.


5. Less Maintenance

When using lead-acid batteries for power supply, regular maintenance is essential to ensure the battery performance. However, when purchasing lithium-ion batteries for power use, less maintenance is required. The lithium-ion cells is more stable with good performance. It saves a lot of time for maintenance and cost for replacement.


Comparision Of Battery


Lithium-ion battery pack Application

8 11.1V 5Ah Lithium battery application6 11.1V 13Ah lithium battery application

6 36V 10Ah lithium battery application

11.1V Lithium-Ion Battery Pack,Solar Lithium Ion Battery,Lithium Ion Battery Rechargeable,Rechargeable Lithium Battery

ShenZhen UFO Power Technology Co., Ltd. , https://www.ufobattery.com